Industrial Gas Burner BNG120
Home / PRODUCTS / Two Stage Gas Burner / Industrial Gas Burner BNG120
  Industrial Gas Burner BNG120
Black Rattan TV Cabinet

Industrial Gas Burner BNG120

♦Gas-fired burner.♦One/Two-stage working.♦350-1200kw

  • Fast Delievery
  • Quality Assurance
  • 24/7 Customer Service
Product Introduction

Question 1-Product Description


SHORT DESCRIPTION

Gas-fired burner.
One/Two-stage working.
Air-gas mixing at blast-pipe.
Ability to obtain optimal combustion values by regulating combustion air and blast-pipe.
Maintenance facilitated by the fact that the atomisation unit can be removed without having to remove the burner from the boiler.
Single stage manual flow adjustment.
Two stage Minimum and maximum air flow regulation for first and second stage by means of electric servomotor with pause closure of gate to prevent any heat dispersion to flue.
One flange and one insulating seal for boiler fastening.
Combustion air intake with air flow adjustment device.
Sliding boiler coupling flange to adapt to head protrusion of the various types of boilers.
Monophase electric motor to run fan.
Flame presence check by ionisation electrode.
Electrical plant protection rating IP40.


PRODUCT VIDEO


Question 2-Product Parameter


BNG85 PARAMETERS

ModelBNG120/BNG120P
FuelNatural Gas (NG)| Propane (LP)|Propane Air Mix (LA)|Town Gas (TG) Digester Gas (DG)
Power(kw)350-1200
Gas Flow(m3/h)35.4-121.4
Power Supply3N AC 50Hz 380V
Motor Power(kw)1.5
Combustion Chamber Pressure(mbar)12
ControlOne/Two stage fire
Packing Size(mm)1250x900x800
Weight(kg) 120

*For more parameters, please contact: info@bntet.com


Question 3-Product Display


BNG120-1

PRODUCT DETAILS

1.Flame stabilising plate
2.Combustion tube
3.Burner body
4.Fire view mirror
5.Motor
6.Electronic Control Cabinet
7.Servo Motor


gas-burner-BNG120-details01

gas-burner-BNG120-details01

gas burner BNG120details02

gas burner BNG120details02


Question 4-Application


gas-burner-application

gas-burner-application02


Question 5-FAQ


Q:Industrial gas burner working principle

A:The working principle is that the gas is mixed with air during transportation to the combustion chamber and ignited with a spark or pilot flame.

Q:How to calculate the gas consumption of an industrial gas burner?

A:(Power[kw] x 3.6) / calorific value of gas [MJ/m3n].

Example:

●Required burner power = 7,220 kW

●The calorific value of natural gas=35.8 MJ/m3n

→Gas consumption = (7,220 kW x 3.6)/35.8 MJ/m3n = 726 m3n/h


Question 6-Our service


package of bntet burner



Hot Tags: industrial gas burner,gas burner,boiler burner,bng120

You Might Also Like